Technical data HKW50

Profile of your new combined heat and power plant

Key technical data
Net electrical power range
30 - 50 kW
Usable rated thermal output
60 - 97 kW (124 kW)
Typical operating hours per year
approx. 8,000 h
Consumption of wood chips per year
approx. 300 t (atro)

Technical data
LiPRO HGW200

Dimensions of the gasworks
Length
6,581 mm
Width
1,597 mm
Height
approx. 2,755 mm
Weight of the gas plant
Weight
approx. 2,800 kg
Minimum dimensions of the installation area of the gasworks
Length incl. minimum maintenance area
10,430 mm
Space requirement for dismantling pyrolysis screw
> 3,849 mm
Width incl. minimum maintenance area
2,400 mm
Fuel
Natural wood chips
P45 Size/standard
Water content
< W10 m-%
Fine fraction
< 5 m-%
Fuel consumption (atro) / kilowatt hour electric
0.71 - 0.81 kg/kWh
Ash/coal volume
0.0016 - 0.0018; (0.5 - 0.57) m³/h; (kg/h)
Wood gas composition
Hydrogen
up to 23 % by volume
Carbon monoxide
up to 21 % by volume
Calorific value
up to 6.1 MJ/N m³
56% are non-flammable components (CO2, N)

Technical data
LiPRO HGM50

Dimensions of the CHP unit
Length
2,507 mm
Width
1,376 mm
Height without feet
1,984 mm
Height with extensions
approx. 2,140 mm
Weight of the CHP unit
Weight
approx. 1,800 kg
Minimum dimensions of the installation area of the CHP unit
Length incl. maintenance area
approx. 3,980 mm
Width incl. maintenance area
approx. 2,300 mm
Key technical data of the CHP unit
Cylinder
6 pcs.
Displacement
8,4 l
Gross rated electrical power
53 kW
Nominal electrical power net
50 kW
Usable thermal output (depending on version)
60 - 97 (124) kW
Net electrical power range
30 - 50 kW
Flow temperature (by module)
approx. 85 °C
Return temperature (before module)
< 65 °C

Technical data
LiPRO E-Control 50

Dimensions of the control cabinet
Height
2,200 mm
Width
1,200 mm
Depth
550 mm

Technical data
LiPRO HGF200/300

Dimensions of the gas flare
Height
3,169 mm
Width
600 mm
Diameter
811 mm
Weight of the gas flare
Weight
approx. 150 kg

RENEWABLE.  DECENTRAL.  REGIONAL.